SERVICES

Surfaces: Tile - Interior Finish - Deck

The most common pool and spa surface repair and remodel needs are addressed with the following solutions:


Tile 

▢ Grouting

▢ Replacement

(Materials Available in Standard and Upgraded Colors and Styles)

  • 2" Wide Belly Band (Slope Change) Marking (Slip Resistant)
  • 6"x6" Waterline Wall Tile (Bullnose  or  Flat)
  • 6"x6" Gutterline Trim Wall Tile (Bullnose - Smooth or Non-Skid)
  • 2"x6" Gutterline Trim Wall Tile (Bullnose - Smooth or Non-Skid)
  • 6"x6" Wall Depth Marker with 4" Graphics / Lettering (Smooth - Bullnose or Flat)
  • 2"x6" Step Cap / Step Trim / Step Edge Marking (Non-Skid - Bullnose) 
  • 6"x6" Beam "No Diving" Marker with 4" Graphics / Lettering Tile (Smooth - Bullnose)
  • 6"x6" Deck "No Diving" Marker with 4" Graphics / Lettering (Non-Skid / Slip Resistant)
  • 6"x6" Deck Depth Marker with 4" Numbers and Units (Non-Skid/Slip Resistant)

Other tile styles are available including glass tile, porcelain tile, ceramic tile, frostproof tile in other sizes including 1", 2", 4", and 12".


Interior Finishes 

▢ Acid Wash

▢ Polish

▢ Waterblast

▢ Convert from Fiberglass to Plaster

▢ Refinish: Materials Available in Standard, Upgrade and Premium Upgrade Colors

  • SGM Diamond Brite (Many Colors Approved for Use in Commercial Pools)
  • CL Industries Krystal Krete (Some Colors Approved for Use in Commercial Pools)
  • CL Industries/Aquavations Hydrazzo (Upgrade) 
  • CL Industries/Aquavations SunStone Pearl Pebble Pool Finish
  • NPT Stonescapes Pebble Pool Finish
  • Premix Marbletite Marquis (A Few Colors Approved for Use in Commercial)
  • Other Pebble, Glass, Marble, and Cement Finishes Available Upon Request.

Decks 

▢ Pressure Wash

▢ Sand

▢ Paint

▢ Apply Acrylic Coating / Spray Deck

▢ Seal

▢ Replace: Materials available in Standard and Upgrade Colors and Styles

  • Brick Pavers (US Paverscapes, Old Castle, Artistic Pavers, Flagstone)
  • Soldier Course Pavers
  • Vertical Pavers
  • Coping
  • Beam
  • Deck drains

Operating & Safety Equipment

▢ Retail Sales and Parts

  • Circulation Equipment: Pumps, Motors, Piping, Valves, Flowmeters, Vacuum Gauges, Pressure Gauges,  Timers, Skimmers, Jets, Main Drain Covers, Suction Outlets, Floor and Wall Returns.
  • Filtration Equipment: Filters (D.E., Cartridge, and Sand)
  • Sanitation and pH Equipment: ORP Controllers, Mechanical Feeders (Stenner), Erosion Feeders
  • Heating Equipment: Heaters and Heat Pumps (LP Gas, Natural Gas, Electric), Thermometers
  • Lighting Equipment: Underwater Lights (LED, Incandescent)
  • Access Equipment (Handrails, Ladders, Chair Lifts)
  • Cleaning Equipment (Robotic Cleaners, Suction and Pressure Cleaners, Hammerhead

▢ Repair

▢ Replacement and New Addition

▢ Conversion to Salt Chlorination

▢ Re-Plumbing

▢ System Re-Engineering

▢ Moving Equipment Pads

▢ Department of Health Code Compliance

▢ Americans with Disability Compliance

▢ Energy Efficiency Audits

▢ Variance Application Support

Routine Cleaning & Maintenance

Weekly Services for Swimming Pools, Spas, Wading Pools Kiddie Pools, and Fountains


Service Plans

  • Full-Service
  • Chemical Testing and Treatment
  • Chemical Checks
  • Temporary Service

Schedule of Service for Commercial Pools

  • 1 Time per Week (Chemical Checks Only)
  • 3 Times per Week
  • 4 Times per Week
  • 5 Times per Week
  • 6 Times per Week  

(We apologize but we are currently not accepting any new Single Family Home Pool / Spa clients at this time.)


Service Tasks 

  • Water Testing: Test the levels of Free Chlorine, pH, Total Alkalinity, Calcium, Cyanuric Acid, and other elements or factors as required by Florida Department of Health 64E-9 codes, Florida Building Codes, and industry standards using the titration method for increased accuracy.
  • Water Adjustment (Balancing):  Introduce EPA-approved, quality chemicals to bring the level of Free Chlorine to a level between 1.5ppm to 10ppm, pH to a level between 7.2 to 7.8, Total Alkalinity to a level between 80ppm and 120ppm, Calcium to a level between 200ppm and 400ppm, Cyanuric Acid to a level between 40ppm and 70ppm (not to exceed 100ppm), and other elements or factors as required by Florida Department of Health 64E-9 codes, Florida Building Codes, and industry standards using the titration method for increased accuracy.
  • Maintenance Logs:  Complete on-site, Florida Department of Health required maintenance logs documenting test results.
  • Tile: Clean waterline tile
  • Empty Baskets: Empty pump basket traps and skimmer basket traps
  • Steps and Walls: Brush steps and walls
  • Vacuum Pool
  • Backwash/Clean Filters
  • Alert management of any equipment needing repair before damage can occur.
  • Alert management of any Florida Department of Health or Florida Building Code inspection violations.